SYSCTL VLNC2 Circuit Pack LEDs
Compatible Software Operation |
FAULT
CR/MJ
MN/ABN
UPD/INIT
ACO/TST |
If compatible software is installed on the replacement
circuit pack, the SYSCTL exibits the following visible cycles:
1. All LEDs light (CR/MJ, FAULT, MN/ABN,
ACO/TST) for approximately 5 seconds.
2. CR/MJ &
FAULT LEDs extinguish & the
MN/ABN &
ACO/TST LEDs remain lighted for
approximately 15 seconds & then extinguish for 5 seconds.
3. MN/ABN &
ACO/TST LEDs simultaniously light
again for 8 seconds & then extinguish after 15 seconds.
4. CR/MJ LED flashes eleven times.
5. The LEDs return to the previous state (prior to the replacement)
indicating that there is compatible software installed on the
replacement circuit pack. |
Factory Default SYSTCTL VLNC2
LEDs |
FAULT
CR/MJ
MN/ABN
UPD/INIT
ACO/TST |
If no software is installed on the replacement circuit
pack (factory-fresh), the SYSCTL exibits the following visible cycles:
1. All LEDs light (CR/MJ, FAULT, MN/ABN,
ACO/TST) for approximately 5 seconds.
2. CR/MJ &
FAULT LEDs extinguish & the
MN/ABN &
ACO/TST LEDs remain lighted for
approximately 15 seconds & then extinguish for 5 seconds.
3. MN/ABN &
ACO/TST LEDs simultaniously light
again for 8 seconds & then extinguish after 5 seconds.
4. CR/MJ LED flashes eleven times.
On flashes 3, 4, 7, 8 & 11, the MN/ABN
& ACO/TST LEDs simultaneously light
while the CR/MJ LED flashes. On
flashes 1, 2, 5, 6, 9 & 10, only the CR/MJ
LED flashes.
5. CR/MJ LED remains lighted & the
MN/ABN &
ACO/TST LEDs simultaneously flash
slowly (light for 2 seconds, extinguish at 2 seconds) indicating that
the SYSCTL is factory-fresh. |
Incompatible Software LEDs on SYSCTL VLNC2 |
FAULT
CR/MJ
MN/ABN
UPD/INIT
ACO/TST |
If incompatible software is installed on the replacement
circuit pack, the SYSCTL exibits the following visible cycles:
1. All LEDs light (CR/MJ, FAULT, MN/ABN,
ACO/TST) for 5 seconds.
2. CR/MJ &
FAULT LEDs extinguish & the
MN/ABN
LED lights & MN/ABN & ACO/TST
LEDs remain lighted for 15
seconds & then extinguish for 5 seconds.
3. MN/ABN &
ACO/TST LEDs simultaniously light
again for 8 seconds & then extinguish after 5 seconds.
4. CR/MJ LED lights wile the
ACO/TST LED flashes.
5. Find circuit pack with compatible software or boot code & repeat
procedure or simultaneously depress the
ACO/TST push-button & the UPD/INT
recessed push-button on the faceplate of the SYSCTL until the
FAULT LED lights.
6. MN/ABN &
ACO/TST LEDs simultaniously light
again for 15 seconds & then extinguish for 8 seconds.
7. MN/ABN &
ACO/TST LEDs simultaneously light
again for 10 seconds & then extinguish for 15 seconds.
8. CR/MJ LED remains lighted & the
MN/ABN &
ACO/TST LEDs simultaneously flash
slowly (light for 2 seconds, extinguish at 2 seconds) indicating that
the SYSCTL is now ready to accept a download. |
SYSCTL VLNC52 |
FAULT |
If a Circuit pack has failed, incoming
electrical/optical signal failure will light the
FAULT LED red and it will flash on
& off in one-second intervals.
If the FAULT LED is unlit circuits
are functioning properly. |
ACTIVE |
If the ACTIVE LED
is flashing means a Firmware Smart Apply may begin.
If ACTIVE LED is solid green this
means it is operating normally. |