IWATSU DTI-PT Card
Normal Status Lights
Light |
STATUS |
Description & Suggested Action |
REDALM | Red (Solid) | Red alarm. No signal from Carrier. Likely a complete circuit failure or break. The most severe alarm. // Call your Carrier. |
YELALM | Yellow (Solid) | Carrier is not receiving signal but your equipment is getting this signal from the Carrier. // Call your Vendor & Carrier. |
ERRST | Red (Solid) | PRI is running CRC or framing errors errors likely due to improperly configured Carrier equipment or poor line quality. // Report to your Carrier. |
Complete Description of Lights
LED |
Description |
Status |
||
On | Off | Flash | ||
REDALM | Red Alarm LED | Red Alarm | No Red or Blue Alarm |
AIS (Blue) Alarm |
YELALM | Yellow Alarm LED | Yellow Alarm | No Yellow Alarm | N/A |
ERRST | Error Status LED | CRC/Framing Error or BipolarViolation Detected |
No Errors | N/A |
M/S | Master/Slave Mode Setting Indication LED |
Master Mode Setting | Slave Mode Setting | N/A |
CLKM | Clock Master Indication | Clock Source | Not Synchronized | Synchronized with master (500ms on 500 ms off). This is the slave card in a 2 or more T1/PRI system. |
OPR0 | Layer 1 Connection Status | Layer 1 issue | normal | N/A |
OPR1 | Layer 2 Connection Status | Layer 2 issue | normal | N/A |
OPR2 | Initialization Status | N/A | No Data Transmission | Initialization Data Transmission |
MB | Make Busy LED | Busy with calls | Idle, no calls | In Make Busy and no active calls, new calls are prevented. |